10, 15, 25, 37.5, 50, 75, 100, 167, 250, 330KVA
HANSYEN
| Availability: | |
|---|---|
Product Description
HANYSEN Oil-filled single-phase overhead transformers designed and produced normally used for stepping utility distribution voltages(ranging from 2400 to 34500 volts) down to lower utilization voltages. Although some are used for stepping down to commercial and industrial voltages such as 277, 240/480, 2400 and 4800,most are used for stepping down to the single-phase voltage of 120/240.These same transformers are also used for small substations,miscellaneous applications and can serve to step up voltages.
Applications
Residential
Commercial & Industrial sectors
Agricultural
Distribution networks expansion or modernization
Key Features & Differentiators
Safety Protection Options
Over current protection, Arresters protection.
Standards Compliance: All transformers are manufactured to meet and exceed ANSI. NEMA, DOE, lEEE and CSA standards, ensuring compatibility and safety.
Construction: Durable tank design with high-grade silicon steel cores provides long-lasting performance in demanding conditions.
Reliability: High-quality materials and rigorous testing ensure long-term durability.
Flexibility: Available in different configurations to meet specific installation and operational requirements.
Cooling System: Equipped with effective cooling mechanisms for optimal performance in various environments.
Mounting: Compact, lightweight design with easy-to-install mounting brackets.
Main Standards
IEEE Std C57.12.00™
IEEE Std C57.12.20™
IEEE Std C57.12.30™
IEEE Std C57.12. 31™
IEEE Std C57.12. 39™
IEEE Std C57.12.70™
IEEE Std C57.12.80™
IEEE Std C57.12.90™
IEEE Std C57.91™
CSA C2.2, 1st Ed
DOE 10 CFR Part 431, DOE 2016
Standard Features
Lifting Lugs
Support lugs: type A for 10-50kVA, type B for 75-167kVA
High Voltage porcelain bushings, with eyebolt or spade terminals, 1 or 2
Low Voltage bushings, with eyebolt or spade terminals
Tank and covers: Stainless steel or carbon steel
Recessed tank bottom
Tank Grounding provision and connector
Low-voltage grounding connection and connection strap
Winding: Aluminum or Copper
Electrical grade mineral oil or FR3 fluid
Laser-engraved nameplate
Inner oil level indicator
Pressure Relief Device
Meets DOE Energy Efficiency Standard
Permanently identification Per IEEE Std C57.12.70 and customer requirement
Optional Features
HV Surge arrester
Primary Internal current limiting fuse and protective link
External De-energized Tap-changer
External dual voltage switch
IFD sensor (Internal Fault Detector)
Routine Tests
Resistance measurements test
Ratio test
Polarity and phase relation tests
No-load losses and excitation current test
Impedance voltage and load loss test
Applied voltage test
Induced voltage test
Lightning impulse test
Leak test
Components
Figure A: Primary fuse
Figure B: Primary heavy-duty surge arrester
Figure C: Primary tap change switch
Figure D: HV bushing: ANSl standard, porcelain insulator, for BlL 95-150kV, aluminum bronze precision casting
Figure E: LV bushing: ANSl standard, eyebolt style or spade, porcelain insulator, aluminum bronze precision casting
Routine Tests
Resistance measurements test
Ratio test
Polarity and phase relation tests
No-load losses and excitation current test
Impedance voltage and load loss test
Applied voltage test
Induced voltage test
Lightning impulse test
Leak test
Diagram: 1 or 2 HV Bushings